60KW Diesel Generator on Trailer...97hrs - (Lubbock for sale in Odessa, Texas

$8,395

Trailer mounted continuous duty rated Military 60 KW, 3-phase (This can also be modified to supply about 50KW of 120/240 single phase for a $200 set up charge..) 60HZ Diesel Powered generator on a heavy duty trailor. Very Heavy duty unit and in very nice condition. Starts instantly and runs smoothly. Load tested at 75KW for one hour and pulled it without a problem. Below are some specs from the military manual.
Fuel:
Primary: VV-F-800: Diesel Fuel Oil, types DF-1, DF-2 and DF-A.
Emergency Fuel: MIL-T-5624, Aviation Turbine Fuels, grades JP-4 an JP-5.
Electrical:
Drip proof generator enclosure. Capable of parallel operation. Fungus and
moisture treatment. Solid state voltage regulator. Brushless rotary exciter.
Voltage Connection: 60 Hz: 120/208 V, 3 phase, 4 wire. 240/416 V, 3 phase,
4 Wire.
Adjustment Range for Standard Voltage Connections
120/208 V Con: 60 Hz: 114 to 136 V / 197 to 240 V.
240/416 V Con: 60 Hz: 218 to 276 V / 395 to 480 V.
Engine: Diesel. turbocharged Allis Chalmers 3500, 7 liter. No. of
cyl: 6. Cycle: 4. Liquid cooled. 24 VDC electric start. Operating speed:
50 Hz: 1500 RPM, 60 Hz: 1800 RPM. Fuel tank capacity: 55 gallons. Fuel pump lift: 12 feet.
Protective Devices:
Short circuit protection. Overvoltage protection.
Overload protection. Reverse power protection. Low oil pressure cut-off
switch. High temperature cut-off switch. Low fuel level cut-off switch.
Overspeed cut-off switch.
Instrumentation:
Voltmeter. Frequency meter. Ammeter. Hourmeter. Wattmeter
(% load). Oil pressure gage. Battery charging ammeter (% current). Fault
indicating system. Coolant temperature gauge. Fuel level.
Fuel Consumption: 6 gph at 60kw rated load.
Frequency Adjustment Range: 58 to 62 Hz. 48 to 52 Hz.
This generator is mounted on a heavy duty trailer with like new tires. It is a very nice unit and has only 97 hours on the meter. Should run another 20,000 or so before major service is required. I have another identical unit available with 3300 hours on the meter. I will take 7500 for it.
Military generators are very under-rated as to output. They generally will develop up to 20-40% more power than their military rating. I load tested this unit at 75KW for an hour and it carried the load with no problems.
David

Location: Lubbock


Similar categories
Nearby Cities
Copyright © 2024 Americanlisted.com, All Rights Reserved.